Pipeline Accessories

Features:

  • Allows plugging of oxygen flowmeter & probes from front.

  • Bears weight of the metal BPC  flowmeter & humidifier.

  • Push to insert and press-to-release mechanism for flowmeters & probes.

  • Locating terminal unit pin & probe notch gives maximum stability to the flowmeter unit.

  • Non-interchangeability between probes & terminal outlets for different services; possibility of error in making connection is avoided.

  • Safety key plug used with Schrader type self sealing valves can also be used on the terminal units so that existing ancillary equipment can be inserted in both the terminal units as well as Schrader type sealing valves.



terminal_units_thumb

Terminal Units

3460 - Oxygen (White)    3461 - Nitrous Oxide (Blue)
3462 - Air (Grey)    3463 - Vacuum (Yellow)

direct_probes_thumb

Direct Probes

3450 - Oxygen (White)    3451 - Nitrous Oxide (Blue)
3452 - Air (Grey)    3453 - Vacuum (Yellow)

3301_single_pipeline_adap_thumb

Single Pipeline Adaptor

3301 - Oxygen
Making & breaking the supply connection is in the same manner as described under “Self Sealing Valves”

twin_pipeline_adap_thumb

Twin pipeline adaptor

3302 - Oxygen
Making & breaking the supply connection is in the same manner as described under “Self Sealing Valves”

schrader_self_sealing_thumb

Schrader Self Sealing Valves & Accessories

Illustration shows complete Oxygen Outlet Point (with Twin Pipeline Adaptor & BPC Flowmeters), as would be seen in actual use in wards.

3303_self_sealing_valves_thumb

Self Sealing Valves (Schrader types)

3303 - Oxygen    3304 - Nitrous Oxide
3305 - Air    3306 - Vacuum
The outlet points from which gases & vacuum are drawn are  of self sealing type and have non-interchangeable outlet fittings. The supply is established simply by inserting the appropriate safety key plug into the orifice of the outlet point and pressing it home until it locks in position. To break the connection, the milled collar round the orifice is rotated a few degrees to the right, when the safety key plug is automatically ejected and the gas flow is cut off.

3307_safety_key_plus_schrader_thumb

Safety key plugs (Schrader type)

3307 - Oxygen    3308 - Nitrous Oxide
3309 - Air    3310 - Vacuum
These are non-interchangeable like the self sealing valves and thus eliminate the possibility of errors in making connections.

3315_s_bracket_thumb

'S' Bracket

3315 - For connecting the down drop pipes to self sealing valves.

3311_plastic_covers_for_self_sealing_valves_thumb

Plastic Covers for self sealing valves

3311 - Oxygen    3312 - Nitrous Oxide
3313 - Air    3314 - Vacuum
Coloured coded text for respective self sealing valves to safe guard against the possibility of administering the wrong gas.

minimum_contact_guages_thumb

Minimum contact guages & Gas Failure Alarm for pipelines

3324 - 0 - 250kg/cm2 High Pressure, Oxygen, Dia 100mm
3326 - 0 - 10kg/cm2 Low Pressure, Oxygen, Dia 100mm
3350 - Pipeline Gas Failure Alarm
The contact gauge has electrical contacts. It should be connected to the pipeline gas failure alarm which has two signal lights, a buzzer & an “ON/OFF” switch. When the contact  gauge is connected to the power supply and the ON/OFF switch of the alarm is switched “ON”, green light will show indicating that the electrical supply serving the contact gauge & alarm are working correctly. The green light should show at all times when the pipeline is in use. The other signal light viz red is a warning light which automatically shows & the buzzer rings when the pressure in the running cylinder has fallen to a determined value. Put the switch to “OFF” position after which the reserve cylinder should be brought into operation promptly to ensure continuity of supply.

high_pressure_tubimg_thumb

High Pressure Tubing - 6 mm I.D

3730 - Grey     (Air)
1211 - Yellow   (Vacuum)
3729 - Blue     (Nitrous Oxide)   
3726 - White   (Oxygen)
3731 - Black   (Carbon Dioxide)

raos_vaccum_regulator_thumb

Rao's Vaccum Regulators

1203 - 0 to 760mm Hg.    1230 - 0 to 200mm Hg.    1220 - 0 to 500mm Hg.
Rao’s range of vacuum regulators represents the ultimate in vacuum control. High (0-760mm Hg), Medium (0-500mm Hg) & Low suction (0-200mm Hg).  These cover all the medical central pipeline applications of the operation theatres & wards.
The regulator comprises of a polymer body which houses an ON/OFF lever, an adjustable knob at the front, a large diaphragm for accurate suction control and a vacuum gauge with different scales depending on model 760, 500 & 200.  The ON/OFF lever allows the operator to start or stop suction by turning the lever, with the adjustable knob, the operator can set the amount of vacuum necessary. The medium & low volume regulators have a safety valve set to open between 450 & 475mm Hg for medium suction and between 150 & 175mm Hg for low suction.

vaccum_units_thumb

Vaccum units

1250 - 600ml   
1201 - 1000ml
1202 - 2000ml
1260 - 4000ml
Vacuum units are available in 600, 1000, 2000 & the new 4000ml capacity. The jars are made of polycarbonate, practically unbreakable, shatter resistant and autoclavable at 1340 C. ABS is used for other components to withstand hard usage and provide trouble free service over a long period of time. A stainless steel bracket is provided on the cap as a separate component and not as an integral part of the cap to avoid the cap breaking, when the jar gets filled with suction fluids. The bracket fits directly on the mounting bracket on the wall. A well proven fluid control trap fitted on the unit automatically and efficiently shuts off vacuum fully, preventing the transfer of liquid to the vacuum regulator, pipeline and pump.

1263_thumb

Safety Jar

1263
The Safety Jar comprises of a cap with well proven fluid control trap and an autoclavable polycarbonate clear jar.  It is fitted between the primary vacuum units and the vacuum regulator to protect the system from aspirated fluids entering the regulator, pipeline and pump.
In the interest of greater safety & efficiency, we have specially designed the unit for this purpose and to fall in line with international practice.

1300_raos_twin_carry_vaccum_unit_thumb

Rao's Twin Carry Vaccum Unit

1300
Set comprises : 2000ml Ward Vacuum units X 2 (1202), Rao’s Vacuum Regulator Model 760 (1203), & Twin Carry Vacuum Stand (1285)
Light but sturdy, stainless steel stand to accommodate two 2000ml jars with a vacuum regulator to easily carry from one place to another as & when required. Specially useful in operation theatres & wards in hospitals and nursing homes.
The regulator comprises of a polymer body which houses an ON/OFF lever, an adjustable knob at the front, a large diaphragm for accurate suction control and a vacuum gauge with different scales depending on model 760, 500 & 200.  The ON/OFF lever allows the operator to start or stop suction by turning the lever, with the adjustable knob, the operator can set the amount of vacuum necessary. The medium & low volume regulators have a safety valve set to open between 450 & 475mm Hg for medium suction and between 150 & 175mm Hg for low suction.

1200_thumb

Rao's Theatre Vaccum Unit with Trolley

1200
Set comprises : 4000ml Vacuum units X 2 (1260), Rao’s Vacuum Regulator Model 760 (1203), Safety Jar with overflow safety device (1263) & Theatre Trolley (1264)
The basic trolley consists of a stand on four castor wheels; very stable and provided with an easy grip handle for convenient transportability.  It is suitable for two 4000ml capacity suction units, a high/medium/low vacuum regulator & a safety jar fitted with an overflow safety device.